F6150 Technical Specifications
Overview Technical Specifications Product Options Software
SOURCES
Total Sources
The F6150 can provide up to 12 simultaneous user-configurable AC/DC sources, including 6 convertible sources and 6 current sources.
Convertible Sources
Each 150 VA convertible source can be used as a voltage source or optionally as a high-power, low-range current source. The F6150 has up to 6 convertible sources.
Source Configurations
|
Output Power (VA)
|
Number of Sources
|
|
Continuous
|
Transient for
1.5 Seconds
|
|
|
75
|
97.5
|
6
|
|
150
|
195
|
3
|
|
300
|
390
|
1 + 1 (150 VA) or 1 + 2 (75 VA)
|
|
450
|
585
|
1
|
Each 150 VA convertible source can be split into two 75 VA sources.
Two 150 VA convertible sources can be combined in parallel into one 300 VA current source.
Three 150 VA convertible sources can be combined in parallel into one 450 VA current source.
Ranges and Resolution
|
|
Source (VA)
|
|
|
75
|
150
|
300
|
450
|
|
AC Voltage
|
75, 150 V RMS (0.01 V)
|
75, 150 V RMS (0.01 V)
|
|
|
|
DC Voltage
|
106, 212 V DC (0.01 V)
|
106, 212 V (0.01 V), 300 V DC (0.1 V)
|
|
|
|
AC Current
|
|
Transient
|
0.75, 1.5 A RMS (0.0001 A)
|
0.75, 1.5, 3.0 A RMS (0.0001 A)
|
1.5, 3.0, 6.0 A RMS (0.001 A)
|
2.25, 4.5, 9.0 A RMS (0.001 A)
|
|
Continuous
|
0.5, 1.0 A RMS (0.0001 A)
|
0.5, 1.0, 2.0 A RMS (0.0001 A)
|
1.0, 2.0, 4.0 A RMS (0.001 A)
|
1.5, 3.0, 6.0 A RMS (0.001 A)
|
|
DC Current
|
|
Transient
|
0.53, 1.06 A DC (0.0001 A)
|
0.53, 1.06 A (0.0001 A),
2.12 A DC (0.001 A)
|
1.06 A (0.0001 A),
2.12, 4.24 A DC (0.001 A)
|
1.59 (0.0001 A),
3.18, 6.36 A DC (0.001 A)
|
|
Continuous
|
0.354, 0.707 A DC (0.0001 A)
|
0.354, 0.707 A (0.0001 A),
1.41 A DC (0.001 A)
|
0.707 A (0.0001 A),
1.41, 2.83 A DC (0.001 A)
|
1.06, 2.12, 4.24 A DC (0.001 A)
|
Current Sources
The F6150 has up to 12 current sources available: 6 current sources and 6 high-power, low-range convertible sources.
Source Configurations
|
Output Power (VA)
|
Number of Sources
|
|
Continuous
|
Transient for
1.5 Seconds
|
|
|
75
|
112.5
|
6
|
|
150
|
225
|
3
|
|
300
|
450
|
1 + 1 (150 VA) or 1 + 2 (75 VA)
|
|
450
|
675
|
1
|
Each 150 VA current source can be split into two 75 VA current sources.
Two 150 VA current sources can be combined in series or in parallel into one 300 VA current source.
Three 150 VA current sources can be combined in parallel into one 450 VA current source.
Ranges and Resolution
|
|
Source (VA)
|
|
|
75
|
150
|
300
|
450
|
|
AC Current
|
|
Transient
|
15, 30 A RMS (0.001 A)
|
15, 30 A (0.001 A),
60 A RMS (0.01 A)
|
15, 30 A (0.001 A),
60, 120 A RMS (0.01 A)
|
15, 30 A (0.001 A),
45, 90, 180 A RMS (0.01 A)
|
|
Continuous
|
7.5, 15 A RMS (0.001 A)
|
7.5, 15 A (0.001 A),
30 A RMS (0.01 A)
|
7.5, 15 A (0.001 A),
30, 60 A RMS (0.01 A)
|
7.5, 15, 22.5 (0.001 A), 45, 90 A RMS (0.01 A)
|
|
DC Current
|
|
Transient
|
10, 20 A DC (0.01 A)
|
10, 20, 40 A DC (0.01 A)
|
10 A (0.001 A),
20, 40, 80 A DC (0.01 A)
|
10 A (0.001 A),
20, 30, 60, 120 A DC (0.01 A)
|
|
Continuous
|
5 A (0.001 A),
10 A DC (0.01 A)
|
5 A (0.001 A),
10, 20 A DC (0.01 A)
|
5 A (0.001 A),
10, 20, 40 A DC (0.01 A)
|
5 A (0.001 A),
10, 15, 30, 60 A DC (0.01 A)
|
TECHNICAL
AC Amplitude Accuracy at 50/60 Hz Voltage and Current Sources
From 20° to 30° C: <0.02% typical, 0.09% guaranteed. Typically 0.02% of reading
Convertible Source in Current Mode
From 20° to 30°C: <0.5% guaranteed
Distortion at 50/60 Hz Voltage and Current Sources
Total Harmonic Distortion (THD): < 0.02% typical < 0.1% guaranteed
Phase Angle
Range: 0 to +359.9° (Lead) / 0 to –359.9° (Lag)
Accuracy: ±0.25° at 50/60 Hz
Resolution: ±0.1° at 50/60 Hz
Frequency
Bandwidth: DC to 3 kHz at full power for transient playback
Range: DC; AC from 0.1 Hz to 2 kHz at full power continuous load
Resolution: 0.001 Hz
Accuracy: 0.5 ppm (typical), 1.5 ppm (20° to 30° C), 10 ppm (0° to 50° C)
Ramp/Set
Ramp: Increments/decrements voltage, current, phase angle, and frequency at user defined ramp rates. Ensures smooth, linear changes in value.
Metering Functions
DC Meter Inputs
Input Range: 0 to ±10V DC or 0 to ±20 mA DC
Accuracy: <0.003% typical, <+0.05% guaranteed
AC Sources
Accuracy: <0.02% for typical meter loads
Logic Inputs as Counters
Frequency: 10 kHz
Pulse Width: >175 microseconds
Logic Inputs
Number of Logic Inputs: 8 total
Isolated Inputs: 2
Configurable as Voltage Sense or Contact Sense
Voltage Sense: Up to 250 V AC or DC
Open Circuit Test Voltage: 12 VDC nominal
Short Circuit Test Current: 20 mA DC nominal
Response Time: 0.1 millisecond max pickup and dropout
Isolation: ±500 V peak
Paired Logic Inputs: 3 pairs (6 total)
Configurable as Voltage Sense or Contact Sense
Voltage Sense: Up to 250 V AC or DC
Open Circuit Test Voltage: 4 Volts DC nominal
Short Circuit Test Current: >50 mA DC nominal
Response Time: 0.1 millisecond max pickup & dropout
Isolation: ±500 V peak
Logic Outputs
Number of Logic Outputs: 8
Configurable as Normally Open (NO) or Normally Closed (NC) switches
High-Speed Electronic Switches: 4
Input Voltage: 250 V DC or AC
Switching Current: 0.5 A make or break, maximum
Response Time: 0.1 millisecond maximum pickup and dropout
Isolation: ±500 V peak
Outputs: Relays: 4
Breaking Cap AC: 2000 VA with Vmax 250 V, Imax 8 A
Breaking Cap DC: 50W with Vmax 300 V, Imax 8 A
Response Time: <10 millisecond max pickup and dropout
Isolation between Pairs: ±500 V peak
Variable Output Battery Simulator
Range: Adjustable 6 to 300 VDC
Resolution: 0.3 V
Power: 90 W, 1.5 A max
50/60 Hz Ripple: <0.2% of range
Accuracy: < +/- 5%
Analog Input Measurement (F6820 Option)
Recording: 8 external analog and digital channels
Source Recording: 12 internal sources
Ranges: 250 mV RMS, 2.5 V RMS, 25 V RMS, 250 mV RMS
Accuracy: ±0.06% typical, ±0.15% maximum
Bandwidth: DC to 5 kHz
Input Impedence: 150k ohms
Max. Input Voltage: 250 V RMS/DC
Isolation: ±500 V peak channel-to-channel
Timers and Triggers
Timers
Number: 8
Max Recording Time: <24 hours
Accuracy: ±0.0005% of reading, ±50 microseconds
Resolution: 100 microseconds
Time can be displayed as milliseconds, seconds, or cycles
Triggers
Number: 8
Boolean combination of logic inputs can be used to define triggers
GENERAL
Quality Assurance Management System
Third-party certification to ISO 9001:2000
Calibration
Certification traceable to N.I.S.T. standards
Electrostatic Discharge Immunity
IEC 801-2 I.E.C. performance level 1 @ 10 kV: normal performance within specifications. I.E.C. performance level 2 @ 20 kV: no permanent damage.
Surge Withstand Capability
ANSI/IEEE C37.90. The instrument functions as a source during surge withstand capability tests, when the ANSI/IEEE specified isolating circuit is interposed between the instrument and the test relay.
Interfaces: RS 232 or Ethernet control to PC
Line Power Supply: 105–132 V or 210–264 V, 47–63 Hz
EMC: CE conform (89/336/EEC) and EN 61326-1
Emission: FCC 47 CFR Part 15 Class A, EN 61326
Safety: EN 61010-1, EN 61010-2-31, IEC 61010-1
Operating Temperature: 0° to 50° C (32° to 122° F)
Storage Temperature: –50° to 85° C (–58° to 185° F)
Humidity: Up to 95% relative humidity, non-condensing
Enclosure
High impact, molded, flame retardant ABS. Meets National Safe Transit Association testing specification No. 1A for immunity to severe shock and vibration.
Dimensions
15 x 9.5 x 18 inches (38 x 24 x 45.7 cm)
Weight
38.3 lb (17.4 kg) (with front cover and carrying strap)
PC Communication
Communication between PC to F6150 via Ethernet 10 BaseT or via serial RS 232 port. Self-diagnostics of the hardware upon each startup. Automatic supervision and error checking on voltage and current source outputs during testing.
Specifications are subject to change without notice.
For assistance with Doble protection products and software, please email fserieshelp@doble.com.
Doble is an ISO 9001:2000 Certified Company. © 2010 Doble Engineering Company
All Rights Reserved. View our
Privacy Statement.