Products

F6150 Technical Specifications

F6150 Power System Simulator

Overview  Technical Specifications  Product Options  Software 

SOURCES

Total Sources

The F6150 can provide up to 12 simultaneous user-configurable AC/DC sources, including 6 convertible sources and 6 current sources.

Convertible Sources

Each 150 VA convertible source can be used as a voltage source or optionally as a high-power, low-range current source. The F6150 has up to 6 convertible sources.

Source Configurations

Output Power (VA)

Number of Sources


Continuous

Transient for
1.5 Seconds

 

75

97.5

6

150

195

3

300

390

1 + 1 (150 VA) or 1 + 2 (75 VA)

450

585

1

Each 150 VA convertible source can be split into two 75 VA sources.
Two 150 VA convertible sources can be combined in parallel into one 300 VA current source.
Three 150 VA convertible sources can be combined in parallel into one 450 VA current source.

Ranges and Resolution

 

Source (VA)

 

75

150

300

450

AC Voltage

75, 150 V RMS (0.01 V)

75, 150 V RMS (0.01 V)

 

 

DC Voltage

106, 212 V DC (0.01 V)

106, 212 V (0.01 V), 300 V DC (0.1 V)

 

 

AC Current

   Transient

0.75, 1.5 A RMS (0.0001 A)

0.75, 1.5, 3.0 A RMS (0.0001 A)

1.5, 3.0, 6.0 A RMS (0.001 A)

2.25, 4.5, 9.0 A RMS (0.001 A)

   Continuous

0.5, 1.0 A RMS (0.0001 A)

0.5, 1.0, 2.0 A RMS (0.0001 A)

1.0, 2.0, 4.0 A RMS (0.001 A)

1.5, 3.0, 6.0 A RMS (0.001 A)

DC Current

   Transient

0.53, 1.06 A DC (0.0001 A)

0.53, 1.06 A (0.0001 A),
2.12 A DC (0.001 A)

1.06 A (0.0001 A),
2.12, 4.24 A DC (0.001 A)

1.59 (0.0001 A),
3.18, 6.36 A DC (0.001 A)

   Continuous

0.354, 0.707 A DC (0.0001 A)

0.354, 0.707 A (0.0001 A),
1.41 A DC (0.001 A)

0.707 A (0.0001 A),
1.41, 2.83 A DC (0.001 A)

1.06, 2.12, 4.24 A DC (0.001 A)

Current Sources

The F6150 has up to 12 current sources available: 6 current sources and 6 high-power, low-range convertible sources.

Source Configurations

Output Power (VA)

Number of Sources


Continuous

Transient for
1.5 Seconds

 

75

112.5

6

150

225

3

300

450

1 + 1 (150 VA) or 1 + 2 (75 VA)

450

675

1

Each 150 VA current source can be split into two 75 VA current sources.
Two 150 VA current sources can be combined in series or in parallel into one 300 VA current source.
Three 150 VA current sources can be combined in parallel into one 450 VA current source.

Ranges and Resolution

 

Source (VA)

 

75

150

300

450

AC Current

   Transient

15, 30 A RMS (0.001 A)

15, 30 A (0.001 A),
60 A RMS (0.01 A)

15, 30 A (0.001 A),
60, 120 A RMS (0.01 A)

15, 30 A (0.001 A),
45, 90, 180 A RMS (0.01 A)

   Continuous

7.5, 15 A RMS (0.001 A)

7.5, 15 A (0.001 A),
30 A RMS (0.01 A)

7.5, 15 A (0.001 A),
30, 60 A RMS (0.01 A)

7.5, 15, 22.5 (0.001 A), 45, 90 A RMS (0.01 A)

DC Current

   Transient

10, 20 A DC (0.01 A)

10, 20, 40 A DC (0.01 A)

10 A (0.001 A),
20, 40, 80 A DC (0.01 A)

10 A (0.001 A),
20, 30, 60, 120 A DC (0.01 A)

   Continuous

5 A (0.001 A),
10 A DC (0.01 A)

5 A (0.001 A),
10, 20 A DC (0.01 A)

5 A (0.001 A),
10, 20, 40 A DC (0.01 A)

5 A (0.001 A),
10, 15, 30, 60 A DC (0.01 A)

TECHNICAL

AC Amplitude Accuracy at 50/60 Hz Voltage and Current Sources

From 20° to 30° C: <0.02% typical, 0.09% guaranteed. Typically 0.02% of reading

Convertible Source in Current Mode

From 20° to 30°C: <0.5% guaranteed

Distortion at 50/60 Hz Voltage and Current Sources

Total Harmonic Distortion (THD): < 0.02% typical < 0.1% guaranteed

Phase Angle

Range: 0 to +359.9° (Lead) / 0 to –359.9° (Lag)
Accuracy: ±0.25° at 50/60 Hz
Resolution: ±0.1° at 50/60 Hz

Frequency

Bandwidth: DC to 3 kHz at full power for transient playback
Range: DC; AC from 0.1 Hz to 2 kHz at full power continuous load
Resolution: 0.001 Hz
Accuracy: 0.5 ppm (typical), 1.5 ppm (20° to 30° C), 10 ppm (0° to 50° C)

Ramp/Set

Ramp: Increments/decrements voltage, current, phase angle, and frequency at user defined ramp rates. Ensures smooth, linear changes in value.

Metering Functions

DC Meter Inputs
Input Range: 0 to ±10V DC or 0 to ±20 mA DC
Accuracy: <0.003% typical, <+0.05% guaranteed

AC Sources
Accuracy:
<0.02% for typical meter loads

Logic Inputs as Counters
Frequency:
10 kHz
Pulse Width: >175 microseconds

Logic Inputs

Number of Logic Inputs: 8 total

Isolated Inputs: 2
Configurable as Voltage Sense or Contact Sense
Voltage Sense: Up to 250 V AC or DC
Open Circuit Test Voltage: 12 VDC nominal
Short Circuit Test Current: 20 mA DC nominal
Response Time: 0.1 millisecond max pickup and dropout
Isolation: ±500 V peak

Paired Logic Inputs: 3 pairs (6 total)
Configurable as Voltage Sense or Contact Sense
Voltage Sense: Up to 250 V AC or DC
Open Circuit Test Voltage: 4 Volts DC nominal
Short Circuit Test Current: >50 mA DC nominal
Response Time: 0.1 millisecond max pickup & dropout
Isolation: ±500 V peak

Logic Outputs

Number of Logic Outputs: 8
Configurable as Normally Open (NO) or Normally Closed (NC) switches
High-Speed Electronic Switches: 4
Input Voltage: 250 V DC or AC
Switching Current: 0.5 A make or break, maximum
Response Time: 0.1 millisecond maximum pickup and dropout
Isolation: ±500 V peak

Outputs: Relays: 4
Breaking Cap AC: 2000 VA with Vmax 250 V, Imax 8 A
Breaking Cap DC: 50W with Vmax 300 V, Imax 8 A
Response Time: <10 millisecond max pickup and dropout
Isolation between Pairs: ±500 V peak

Variable Output Battery Simulator

Range: Adjustable 6 to 300 VDC
Resolution: 0.3 V
Power: 90 W, 1.5 A max
50/60 Hz Ripple: <0.2% of range
Accuracy: < +/- 5%

Analog Input Measurement (F6820 Option)

Recording: 8 external analog and digital channels
Source Recording: 12 internal sources
Ranges: 250 mV RMS, 2.5 V RMS, 25 V RMS, 250 mV RMS
Accuracy: ±0.06% typical, ±0.15% maximum
Bandwidth: DC to 5 kHz
Input Impedence: 150k ohms
Max. Input Voltage: 250 V RMS/DC
Isolation: ±500 V peak channel-to-channel

Timers and Triggers

Timers
Number: 8
Max Recording Time: <24 hours
Accuracy: ±0.0005% of reading, ±50 microseconds
Resolution: 100 microseconds
Time can be displayed as milliseconds, seconds, or cycles

Triggers
Number: 8
Boolean combination of logic inputs can be used to define triggers

GENERAL

Quality Assurance Management System

Third-party certification to ISO 9001:2000

Calibration

Certification traceable to N.I.S.T. standards

Electrostatic Discharge Immunity

IEC 801-2 I.E.C. performance level 1 @ 10 kV: normal performance within specifications. I.E.C. performance level 2 @ 20 kV: no permanent damage.

Surge Withstand Capability

ANSI/IEEE C37.90. The instrument functions as a source during surge withstand capability tests, when the ANSI/IEEE specified isolating circuit is interposed between the instrument and the test relay.

Interfaces: RS 232 or Ethernet control to PC
Line Power Supply:
105–132 V or 210–264 V, 47–63 Hz
EMC: CE conform (89/336/EEC) and EN 61326-1
Emission: FCC 47 CFR Part 15 Class A, EN 61326
Safety: EN 61010-1, EN 61010-2-31, IEC 61010-1
Operating Temperature: 0° to 50° C (32° to 122° F)
Storage Temperature: –50° to 85° C (–58° to 185° F)
Humidity: Up to 95% relative humidity, non-condensing

Enclosure

High impact, molded, flame retardant ABS. Meets National Safe Transit Association testing specification No. 1A for immunity to severe shock and vibration.

Dimensions

15 x 9.5 x 18 inches (38 x 24 x 45.7 cm)

Weight

38.3 lb (17.4 kg) (with front cover and carrying strap)

PC Communication

Communication between PC to F6150 via Ethernet 10 BaseT or via serial RS 232 port. Self-diagnostics of the hardware upon each startup. Automatic supervision and error checking on voltage and current source outputs during testing.

Specifications are subject to change without notice.

For assistance with Doble protection products and software, please email fserieshelp@doble.com.


Doble is an ISO 9001:2000 Certified Company. © 2009 Doble Engineering Company