product

ALL VANGUARD TRANSFORMER TURNS RATIO TESTERS

TRF-250
TRF-250 A
TRF-100
ATRT-03 S2
TRI-PHASE
ATRT-01 S3
ATRT-01B S3
CVT-765
FEATURES & BENEFITS
  • Ratio Range: 0.8 – 50,000 to 1
  • Capable of detecting 130 different 3-phase transformer types defined by ANSI, IEC, and Australian standards
  • 4 test voltages: 4Vac, 40Vac, 100Vac, and 250Vac
  • Phase angle and excitation current measurement
  • Bluetooth and USB PC interfaces
  • 4.5-inch wide thermal printer (optional)
CABLES

[8000-0005] USB Cable [ 6' (1.83m) ]
Cable Part Number: 8000-0005

[8000-0009] H Single Phase Cable [ 15' (4.57m) ]
Cable Part Number: 8000-0009

[8000-0010] H Extension Cable [ 25' (7.62m) ]

Cable Part Number: 8000-0010

[8000-0011] X Single Phase Cable [ 15' (4.57m) ]

 Cable Part Number: 8000-0011

[8000-0012] X Extension Cable [ 25' (7.62m) ]
Cable Part Number: 8000-0012

[8000-0013] H 3-Phase Cable [ 15' (4.57m) ]
Cable Part Number: 8000-0013

[8000-0014] X 3-Phase Cable [ 15' (4.57m) ]
Cable Part Number: 8000-0014

[8000-0015] LTC Control Cable [ 15' (4.57m) ]
Cable Part Number: 8000-0015

[8000-0016] Power + Ground Combination Cable
Cable Part Number: 8000-0016

[8000-0186] 3-Phase H Cable [ 30' (9.14m) ]
Cable Part Number: 8000-0186

[8000-0187] 3-Phase X Cable [ 30' (9.14m) ]
Cable Part Number: 8000-0187

[8000-0188] Single-Phase H Cable [ 30' (9.14m) ]
Cable Part Number: 8000-0188

[8000-0189] Single-Phase X Cable [ 30' (9.14m) ]
Cable Part Number: 8000-0189

TECHNICAL SPECIFICATIONS

TYPE Portable, lightweight, automatic 3-phase transformer turns-ratio meter
PHYSICAL SPECIFICATIONS 18”W x 5”H x 12”D (45.7 cm x 12.7 cm x 30.5 cm ); Weight: 20 lbs (9.1 kg)
OPERATING VOLTAGE 100 – 240 Vac, 50/60 Hz
MEASUREMENT METHOD ANSI/IEEE C57.12.90
TURNS-RATIO MEASURING RANGE 0.8 – 50,000 to 1
TURNS-RATIO ACCURACY 0.8 – 1,999: ±0.1%, 2,000 – 3,999: ±0.25%, 4,000 – 14,999: ±1%, 15,000 – 50,000: ±2% @ 4 Vac
0.8 – 1,999: ±0.1%, 2,000 – 3,999: ±0.20%, 4,000 – 14,999: ±1%, 15,000 – 50,000: ±1.5% @ 40 Vac
0.8 – 1,999: ±0.1%, 2,000 – 3,999: ±0.20%. 4,000 – 14,999: ±1%, 15,000 – 50,000: ±1.5% @ 100 Vac
0.8 – 1,999: ±0.1%, 2,000 – 3,999: ±0.15%. 4,000 – 14,999: ±0.8%, 15,000 – 50,000: ±1.2% @ 250 Vac
TEST VOLTAGES 4 Vac @ 1 Amp, 40 Vac @ 200 mA, 100 Vac @ 100 mA, 250 Vac @ 50 mA
EXCITATION CURRENT READING RANGE 0 – 2 Amperes; Accuracy: ±0.1 mA, ±2% of reading (±1 mA)
PHASE-ANGLE MEASUREMENT 0 – 360 degrees; Accuracy: ±0.2 degree ( ±1 digit)
DISPLAY Back-lit LCD screen (128 x 64 pixels) viewable in bright sunlight and low-light levels
PRINTER Optional built-in 4.5-inch wide thermal printer
COMPUTER INTERFACES Bluetooth, USB port
EXTERNAL DATA STORAGE One USB Flash drive interface port; Up to 999 transformer test records can be stored on a USB Flash drive (not included)
INTERNAL TEST RECORD STORAGE Can store 112 transformer test records internally. Each record holds the test record header and up to 99 readings.
INTERNAL TEST PLAN STORAGE Can store 128 transformer test plans internally. Test plans can be transferred to the unit from the PC via Bluetooth/USB port or via the USB Flash drive interface
PC SOFTWARE Windows®-based Transformer Turns Ratio Analyzer application is included with purchase price
LOAD TAP CHANGER CONTACT 240 Vac, 2 Amps
SAFETY Designed to meet UL 61010A-1 and CAN/CSA C22.2 No. 1010.1-92 standards
ENVIRONMENT Operating: -10˚ to 50˚ C (15˚ to +122˚ F); Storage: -30˚ C to 70˚ C (-22˚ to +158˚ F)
CABLES One 15-foot (4.57m) single-phase set, one 15-foot (4.57m) 3-phase set, one 25-foot (7.62m) extension set, one safety ground, one USB, cable bag
OPTIONS Transportation case
WARRANTY One year on parts and labor
Specifications are valid at nominal voltage and ambient temperature of +25˚C (+77˚F).

PART NUMBERS
  • 9105-UC [TRF-250]
  • 9105-PR [TRF-250 built-in thermal printer option]
  • 9105-SC [TRF-250 shipping case]