Phenix Technologies offers a line of portable 40-200 kV DC Hipots with many advanced features.
The high voltage is generated by a filtered high voltage doubler circuit, that is purpose built by Phenix for the exacting demand of high voltage testing.
A solenoid operated discharge switch quickly discharges the load after testing. All high voltage components are housed in an oil filled aluminum sealed grounded dead tank. A shielded high voltage lead allows the operator to safely connect the high voltage output to the test object. The high mA charging current, which is standard with all Phenix DC Hipots allows the operator to quickly and efficiently charge large capacitive loads.
DESIGN & SAFETY FEATURES
Standard Series – Design & Safety Features
Main power circuit breaker switch (with indicator)
External warning circuit provision for safety devices such as flashing light
High Voltage ON/OFF pushbuttons with indicators
Manual control of output voltage
Zero Start interlock
External interlock provision
Overload circuit adjustable from 10% to 110% of rated current
Output overload indicator with reset button
Slow and fast acting transient protection on all meters and relays
Built-in discharge circuit
Very low ripple, <2% RMS at full output
3 ½ digit, multi-range metering
Analog charging currentmeter
Guard mode for accurate current measurements
Thermal resettable overload protecting high voltage transformer primary circuits
“B” Models – Design & Safety Features
Main power circuit breaker switch
External warning circuit provision for safety devices such as flashing light
High Voltage ON/OFF buttons with indicators
Emergency Off pushbutton (Locking)
Automatic voltage control or manual voltage control via infinity dial
USB port for data acquisition via USB drive
WiFi control from PC (Requires optional software)
Auto-ranging meters for total current and specimen return current
Return lead safety locking retention clip
Shielded test current measurement lead
Built-in discharge circuit
Very low ripple, <2% RMS at full output
7” Full-color touch-screen display
HMI displays metering, various controls, and system messages
Breakdown memory voltmeter
Maximum voltage reached memory voltmeter
Duration and Dwell timers
Zero Start interlock
Adjustable rate of rise in Volts/seconds
Adjustable overcurrent trip point
Output overload indication with reset
Insulation Resistance calculation
OPTIONS & ACCESSORIES
Options
Positive polarity output
Custom cable lengths
Calibration data
Ground and Discharge Sticks
Safety Hand Switch with 10’ (3 m) lead
Safety Foot Switch with 20’ (6 m) lead
Windows software for connection to PC (For “B” models Only)