CT-7000 S3
Advanced Digital Circuit Breaker Analyzer
The CT-7000 S3 is Vanguard's fourth generation EHV circuit breaker analyzer. The CT-7000 S3 is available with 3 (part number 9021-UC) or 6 contact timing channels (part number 9100-UC). The CT-7000 S3 can fully analyze a circuit breaker's performance by measuring the main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes. Both contact and motion analysis can be performed on all circuit breaker operations (OPEN, CLOSE, OPEN-CLOSE, CLOSE-OPEN, and OPEN CLOSE-OPEN). The CT-7000 S3's timing window is selectable between 1 second, 10 seconds, and 20 seconds.
| Cable | Part Number |
|---|---|
| [8000-0005] USB Cable [ 6′ (1.83m) ] | 8000-0005 |
| [8000-0097] V1, V2, V3, Trigger Extension Cable [ 30′ (9.14m) ] | 8000-0097 |
| [8000-0099] Initiate Cable [ 22′ (6.71m) ] | 8000-0099 |
| [8000-0101] Test Lead (Trigger, V1, V2) [ 2′ (0.61m) ] | 8000-0101 |
| [8000-0102] Analog Transducer Cable | 8000-0102 |
| [8000-0104] Transducer Cable [ 25′ (7.62m) ] | 8000-0104 |
| [8000-0110] Ground Cable | 8000-0110 |
| [8000-0112] Power Cable | 8000-0112 |
| [8000-0174] CT-7000 S3/8000 S3 Contact Cable (4 pin, 20′) | 8000-0174 |
| [8000-0175] CT-7000 S3/8000 S3 Contact Extension Cable (4 pin, 30′) | 8000-0175 |
| TYPE | Portable circuit-breaker analyzer |
| PHYSICAL SPECIFICATIONS | Dimensions: 21.5”W x 8”H x 14” D (53 cm x 20 cm x 35 cm) Weight: 15 lbs (6.8 Kg) |
| INPUT POWER | 100-240Vac, 3A, 50/60Hz |
| DRY-CONTACT INPUTS | 3 channels (9021-UC) or 6 channels (9100-UC). Channel can detect the main contact and resistor contact time. |
| TIMING WINDOWS | 1 second, 10 seconds, or 20 seconds |
| TIMING RESOLUTIONS | ±50 micro-seconds @ 1 sec. duration, ±500 micro-seconds @ 10 sec. duration, ±1.0 milli-seconds @ 20 sec. duration |
| TIMING ACCURACY | 0.05% of reading ±0.05 ms @ 1 second duration |
| DRY-CONTACT CHANNEL PROTECTION | All contact inputs are grounded until test. Input channels are also protected against static discharge. |
| DRY-CONTACT DETECTION RANGE | Closed: Less than 20 Ohm. Opened: greater than 5000 ohm |
| INSERTION RESISTOR DETECTION RANGE | 50 – 5,000 ohms |
| TRIGGER INPUT VOLTAGE | Open/Close trigger voltage: 24 V – 300V DC or peak AC |
| VOLTAGE SENSING INPUT RANGE | V1: analog input; 0 – 250 V DC or peak AC; sensitivity ±1 V; record and print voltage level V2 and V3: voltage presence/absence detector input; 24 – 255 V DC or peak AC; record and print 3 timing events |
| BREAKER OPERATIONS | Initiate Open, Close, Open-Close, Close-Open, Open-Close-Open |
| BREAKER INITIATE CAPACITY | 30A, 250 Vac/dc max |
| INITIATE CURRENT READING RANGE | one, non-contact, Hall-effect sensor, 0 – 20 amp range, dc to 5 Khz AC |
| DIGITAL TRAVEL TRANSDUCER INPUTS | 3 digital transducer channels; linear range: 0.0 – 60.0 in (±0.01 in) rotary range: 0 – 360 degrees (±0.36 degrees) |
| RESISTOR TYPE TRANSDUCER INPUTS | 3 channels, 200 ohm – 10K ohms |
| CONTACT TRAVEL POINT DIFFERENCE | measures “slow-close” contact-point distances; results can be printed |
| DISPLAY | back-lit LCD screen (128 x 240 pixels); viewable in bright sunlight and low light |
| PRINTER | built-in 4.5” wide thermal printer that can print both graphic contact travel waveforms and tabulated test results |
| INTERNAL TEST RECORD STORAGE | Store up to 200 test records and 100 test plans |
| EXTERNAL TEST RECORD STORAGE | USB Flash drive interface for external storage of test records and test plans |
| COMPUTER INTERFACES | One USB port, optional Bluetooth wireless interface |
| PC SOFTWARE | Windows® based Breaker Analysis software included with purchase price |
| CABLES | furnished with full set of test leads |
| OPTIONS | transportation cases (available for the CT-7000 S3 and travel transducers), on-line timing mode, dual ground testing mode, bluetooth interface |
| SAFETY | designed to meet UL 6101A-1 and CAN/CSA C22.2 No 1010.1-92 standards |
| ENVIRONMENT | Operating: -10°C to +50°C (+15°F to +122°F); Storage: -30°C to +70°C (-22°F to +158°F) |
| HUMIDITY | 90% RH @ 40°C (104°F) non-condensing |
| ALTITUDE | 2,000 m (6,562 ft) to full safety specifi cations |
| WARRANTY | one year on parts and labor |
| Specifications are valid at nominal voltage and ambient temperature of +25˚C (+77˚F). | |